WLAN_1.3.6.1.4.1.2011.6.139.18.1.1.1.14 hwApSipfpmUserFlowFullTrap

Description

WLAN/4/AP_USER_SIPFPM_FLOW_FULL: OID [oid] Reached the maximum number of iPCA flows of the STA. (STAMAC=[OPAQUE], APMAC=[OPAQUE], APName=[STRING], APID=[INTEGER], MaxUserSipfpmFlowNum=[INTEGER])

The number of S-IPFPM flows of a STA on an AP exceeded the threshold.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.6.139.18.1.1.1.14

Warning

qualityOfServiceAlarm (3)

Parameters

Name Meaning

OID

Indicates the ID of a MIB object.

STAMAC

Indicates the MAC address of a STA, which functions as the index for querying its association information.

APMAC

Indicates the MAC address of an AP.

APName

Indicates the AP name.

APID

Indicates the AP ID.

MaxUserSipfpmFlowNum

Indicates the maximum number of S-IPFPM flows of the STA.

Impact on the System

New flows meeting the iPCA analysis criteria of the STA are not added to the flow table.

Possible Causes

The number of flows for iPCA analysis of the STA exceeds the specifications.

Procedure

  1. Adjust the scope of monitored applications to reduce unimportant applications.