Adding a Collector

After the centralized installation is complete, the ATIC Management center automatically creates a collector. You must manually create collectors during the distributed installation.

Procedure

  1. Choose Defense > Network Settings > Collectors.
  2. On the Collectors page, click .

  3. Set other parameters of the collector. For details, see Table 1.

    Table 1 Collector parameters

    Parameter

    Description

    Value

    Name

    Indicates the collector name.

    The name contains a maximum of 32 characters including letters, digits, underscores (_), and hyphens (-)and the name cannot be null. It must start with a letter or an underscore (_).

    IP Address

    Indicates the IP address of the collector.

    The IP address is routable to the IP addresses of the FTP server and log server.

    This parameter cannot be changed during collector modification.

  4. Optional: On the Create Collector page, click Test.

    • If the system displays Succeeded in connecting the collector., perform 5.

    • If the system displays Failed to connect the collector Possible causes: The IP address of the collector is incorrect, or the collector is not started, or the connectivity error occurs., the ATIC Management center and collector cannot be normally connected. Perform the check according to the displayed cause.

  5. On the Create Collector page, click OK.

    After the collector is successfully added, the system displays the Collectors page.

Follow-up Procedure

You can view, modify, or delete a collector by referring to (Optional) Configuring an Collector.


Copyright © Huawei Technologies Co., Ltd.