If the system has heavy service loads, the replacement will increase the service response time. Therefore, perform the replacement during off-peak hours.
Press the release button on the right of the front panel cover, tilt the front panel cover by 20° to 30° forward, and move the front panel cover rightward to separate it from the groove on the left of the system subrack. Then, remove the front panel cover. See (1), (2), and (3) in Figure 1.
Ensure that disk modules are inserted into the same slots before and after the replacement. Otherwise, services may be affected.
After inserting the disk module, wait 5 seconds and then check the disk module running indicator to determine whether the disk module has been successfully installed.
After the metadata disk is replaced, label it to facilitate subsequent operations.