Palm-sized NVMe SSDs are used as main storage disk modules to provide data storage space and are hot-swappable.
When replacing a main storage disk module, ensure that the time from removing the main storage disk module to installing a new main storage disk module into the node does not exceed three minutes. Otherwise, the heat dissipation of the storage device will be affected and the system will be faulty.
Press the release button on the right of the front panel cover, tilt the front panel cover by 20° to 30° forward, and move the front panel cover rightward to separate it from the groove on the left of the system subrack. Then, remove the front panel cover. See (1), (2), and (3) in Figure 1.
Ensure that disk modules are inserted into the same slots before and after the replacement. Otherwise, services may be affected.
After inserting the disk module, wait 5 seconds and then check the disk module running indicator to determine whether the disk module has been successfully installed.
After the main storage disk module is replaced, label it to facilitate subsequent operations.