Replacing Main Storage Disk Modules

Main storage disk modules provide data storage space and are hot-swappable.

Impact on the System

Prerequisites

  • The vendor and type of the spare main storage disk module must be the same as those of the faulty main storage disk module.
  • The capacity of the spare main storage disk module must be greater than or equal to that of the faulty main storage disk module.

Precautions

Recommended Tools

Procedure

  1. Remove a faulty dual-disk disk module.
    1. Press the release button on the ejector lever of the faulty dual-disk disk module and the ejector lever automatically ejects, as shown in step ① in Figure 1.
      Figure 1 Removing a dual-disk disk module
    2. Hold the ejector lever and slowly pull out the dual-disk disk module, as shown in step ② in Figure 1.
  2. Remove the faulty main storage disk module.
    1. Optional: Use a Phillips screwdriver to remove the screws from both sides of the faulty main storage disk module, as shown in step ① in Figure 2. Place the removed screws in an ESD bag for future use.
      Figure 2 Removing screws and disks
    2. Remove the faulty main storage disk module in the arrow direction, as shown in step ② in Figure 2.
  3. Put the removed faulty disk module into an ESD bag.
  4. Take the spare disk module out of its ESD bag.
  5. Install the spare main storage disk module.
    1. Install the spare main storage disk module in the original slot in the arrow direction, as shown in step ① in Figure 3.
      Figure 3 Installing screws and nuts
    2. Use a Phillips screwdriver to tighten the screws obtained in 2.a on both sides of the spare main storage disk module, as shown in step ② in Figure 3.
  6. Install the dual-disk disk module.

    Install the dual-disk disk module into the original slot before the removal. Otherwise, services may be affected.

    1. Open the ejector lever of the spare dual-disk disk module completely and push the module into the node along the slot until the module does not move, as shown in step ① in Figure 4.
      Figure 4 Installing the dual-disk disk module
    2. Close the ejector lever of the dual-disk disk module so that the ejector lever is secured to the node.
  7. Check whether the installation is successful.

    After inserting the dual-disk disk module, wait for one minute and then check the running indicator of the module to determine whether the installation is successful.

    If the running indicator of the dual-disk disk module is steady green, the module is successfully installed. Otherwise, the dual-disk disk module fails to be installed. Perform the following operations:
    1. Check whether the dual-disk disk module has been firmly inserted. If not, wait one minute and reinsert it.
    2. If the dual-disk disk module still fails to be installed after you reinsert it, the link of the disk slot may be faulty. In this case, contact technical support engineers.