#!/bin/bash

G_INSPECT_MMLPATH="/opt/huawei/snas/script/inspect_mml"
. $G_INSPECT_MMLPATH/CheckItems
CurInspectNum="298"
CurInspectFun=`GetInspectType $CurInspectNum`
RESULTFILE="/tmp/tmpResult${CurInspectFun}"
LOG_FILE="/var/log/inspect.log"
>$RESULTFILE

#执行命令: MmlBatch 988 "fc show cfg"|grep fc_switch_disk_disp |awk -F"|" '{print $6}'|tr -d " "
#结果为0,则巡检通过---直接结束
#结果不为0 ,巡检不通过
#当结果不为0 ,并且节点版本是V300R006C00SPC100 时,进行下述规避手段
 #      a) MmlBatch 988 "fc set cfg 4 0"   #关闭流控
  #      b)MmlBatch988 "fc show cfg" | grep fc_switch_disk_disp|awk -F"|" '{print $6}'|tr -d " "
#查看是否更改成功..如果不为0 ,上报一个错误提示
   #     c)sed -i 's/fc_switch_disk_disp=.*/fc_switch_disk_disp=0/g' /opt/huawei/snas/static/base.ini  #持久化
    #          cat /opt/huawei/snas/static/base.ini |grep fc_switch_disk_disp #查看是否持久化成功,如果不为0,上报一个错误提示

function LOG
{
   time=$(date)
   echo [${time}][$$]$@ >> ${LOG_FILE}
}

function main
{
    local ProductVersion=$(grep ProductVersion /opt/huawei/deploy/package/version|awk -F= '{print $2}'|tr -d " " )
    local FluidControlFlag=$(/usr/local/bin/MmlBatch 988 "fc show cfg"|grep fc_switch_disk_disp |awk -F"|" '{print $6}'|tr -d " ")
    local NeedControlVersion="V300R006C00SPC100"
    echo "FluidControlFlag:$FluidControlFlag"
    
    if [ "${ProductVersion}" != "${NeedControlVersion}" -a "${ProductVersion}""X" != "X" ];then
        echo "INFO:THE Version ${ProductVersion} does not needed to be checked." >>${RESULTFILE}
        echo "${CurInspectFun}_Pass 0" >>${RESULTFILE}
        exit 0
    fi
    for i in $(seq 1 3);do
        FluidControlFlag=$(/usr/local/bin/MmlBatch 988 "fc show cfg"|grep fc_switch_disk_disp |awk -F"|" '{print $6}'|tr -d " ")
        if [ "${FluidControlFlag}""X" != "X" ];then
            iret=1
            break
        fi
        if [ "3" == "$i" ];then
            LOG "[$FUNCTION][$LINENO]the command get information failed."
            echo "[ERR]get information failed by mml command(fc show cfg),port(988).ERRCODE(4)" >>${RESULTFILE} 2>&1 
            exit 0
        fi
    done
    
    if [ ${FluidControlFlag} -eq 0 ];then
        echo "INFO:THE FluidControl Flag is 0." >>${RESULTFILE}
        echo "${CurInspectFun}_Pass 0" >>${RESULTFILE}
        exit 0
    else
        echo "[ERR]THE FluidControl Flag is 1.ERRCODE(5)" >>${RESULTFILE}
        #V300R006C00SPC100版本强制关流控
            #关闭流控
            /usr/local/bin/MmlBatch 988 "fc set cfg 4 0"
            if [ $? -ne 0 ];then
                LOG "INFO:THE FluidControl close is failure" >>${RESULTFILE}
            fi
            local Flag=$(/usr/local/bin/MmlBatch 988 "fc show cfg"|grep fc_switch_disk_disp |awk -F"|" '{print $6}'|tr -d " ")
            if [ $Flag -ne 0 ];then
                echo "INFO:THE FluidControl close is failure" >>${RESULTFILE}
            fi
            #持久化
            sed -i 's/fc_switch_disk_disp=.*/fc_switch_disk_disp=0/g' /opt/huawei/snas/static/base.ini
            if [ $? -ne 0 ];then
                LOG "INFO:THE FluidControl close is failure" >>${RESULTFILE}
            fi
            local fileFlag=$(grep -w "fc_switch_disk_disp" /opt/huawei/snas/static/base.ini|awk -F= '{print $2}'|tr -d " ")
            if [ $Flag -ne 0 ];then
                echo "INFO:THE FluidControl close is failure" >>${RESULTFILE}
            fi
        echo "${CurInspectFun}_Pass 1" >>${RESULTFILE}
    fi
}

main