Checking the Hotspare
Procedure
- Check whether an alarm is displayed indicating that a disk is removed from the disk domain (ID: 0x100F00A0010).
For details about how to view an alarm on the DeviceManager, see Checking System Alarms.
- If yes, reinsert the removed disk and go to step 2.
- If no, go to step 3.
- Perform the check again to observe whether the check item fails.
- If yes, go to step 3.
- If no, no further action is required.
- Check whether an alarm is displayed indicating that a disk in the disk domain is abnormal (fault alarm ID: 0xF00A0001, imminent-fault alarm ID: 0xF00A0003, slow-disk alarm ID: 0xF00A000D or 0xF000A005F).
- If yes, use the FRU tool to replace the faulty disk.
- If no, go to step 4.
- Collect related information and contact technical support engineers.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.