Checking BBU Power
How to Handle the Problem if BBU Power Is Insufficient
- Check BBU status.
- If it is normal, go to step 2.
- If it is abnormal, go to step 3.
- Wait until the BBU is fully charged.
- Replace the BBU.
- For Dorado2100 G2, replace the BBU module by referring to Replacing a Fan-BBU Module in the chapter of Replacing Parts in the OceanStor Dorado2100 G2 Storage System V100R001 Troubleshooting.
- For Dorado5100, replace the BBU module by referring to Replacing a BBU in the chapter of Replacing Parts in the OceanStor Dorado5100 Storage System V100R001 Troubleshooting.
Log in to the ISM and choose . Click Events in the Event Management dialog box and select the device and event. Click Query to check whether Recovered At of the BBU module event is displayed.
- If yes, no further action is required.
- If no, go to step 4.
- Collect related information and contact technical support engineers.
Others:
- Contact technical support engineers.