Checking Firmware Version Consistency

An independent 6 Gbit/s SAS interface card is used. Use CLI commands to power on and off the interface card for recovery.

Operation Restriction

Command

poweroffifmodule

Function

poweroffifmodule is used to power off the specified interface module.

Format

poweroffifmodule -c controller id -if interface module id

Description

Key Word and Parameter

Description

Default Value

-c controller id

Controller ID.

The value can be a or b, and the value is case insensitive.

None

-if interface module id

ID of an interface module.

Run the showifmodule command to obtain the ID.

None

Level

Super administrator

Usage Guidelines

Examples

The Dorado5100 is used as an example.

For controller A, power off the interface module with an ID of 0.

admin:/>poweroffifmodule -c a -if 0 
DANGER: You are going to power off the interface card. 

This operation will disable all ports on the interface card. 

Suggestion: Before you perform this operation, ensure that all services related to the interface have been stopped. 
Have you read danger alert message carefully?(y/n) 
y 
Are you sure to perform this operation?(y/n) 
y 
command operates successfully.

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.