Link Status
Procedure
- Check whether the physical connection between the two storage
arrays is cut off.
- If the cable is removed, insert the cable. After the cable is
inserted, run the showrmtlink command in the CLI
to check whether Connection Status is Connected. If no, replace the cable.
- If the cable is damaged, replace the cable. After the cable is
replaced, run the showrmtlink command in the CLI
to check whether Connection Status is Connected. If no, go to step 2.
- If the physical connection is normal, go to step 2.
- Check the remote storage array status.
- If the storage array is faulty, rectify the fault. After the fault
is rectified, run the showrmtlink command in the
CLI to check whether Connection Status is Connected. If no, check whether the storage array is
restarting.
- If the remote storage array is restarting, wait until the restart
completes. After the restart is complete, run the showrmtlink command in the CLI to check whether Connection Status is Connected. If no, go to step 3.
- If the status is normal, go to step 3.
- If you have any questions, please contact technical support
engineers for further handling.