Checking the Upgrade

Context

Table 1 Version Type and Number

Type

Versions Involved

Series 1

  • Dorado5100 V100R001C00

    V100R001C00SPC001

    V100R001C00SPC002

Series 2

  • Dorado2100G2 V100R001C00

    V100R001C00SPC500

    V100R001C00SPC600

    V100R001C00SPC700

    V100R001C00SPCa00

    V100R001C00SPCb00

  • Dorado5100 V100R001C00

    V100R001C00SPC800

    V100R001C00SPC900

    V100R001C00SPCa00

    V100R001C00SPCb00

Series 3

  • Dorado2100G2 V100R001C00

    V100R001C00SPC200

    V100R001C00SPC300

    V100R001C00SPC400

  • Dorado5100 V100R001C00

    V100R001C00SPC004

    V100R001C00SPC600

    V100R001C00SPC700

NOTE:

The following operations do not apply to series 3. Contact Huawei technical support.

Procedure

  1. Series 1: In the CLI, run developer and enter debugging passwords to go to the developer mode. Run debug to go to the debug mode.

    For details about the debugging passwords, refer to Obtaining the Debug Password.

    Series 2: In the CLI, run developer and enter debugging passwords (debug@storage). Run minisystem to go to the minisystem mode.

  2. Run ps -ef |grep upgrade to obtain the PID of the upgrade process.

    For series 1, refer to the following figure.

    For series 2, refer to the following figure.

    • If the operation is successful, go to step 3.
    • If the operation fails, go to step 8.

  3. Run kill -9 process pid to end the upgrade process.
  4. Run ps -ef |grep upgrade to obtain the PID of the upgrade process. Check whether the PID of the upgrade process is changed.

    • If yes, the upgrade ends. No further action is required.
    • If no, go to step 3.

  5. Log in to the other controller and run steps 1 to 4.
  6. Run showupgradepkginfo -t 1.

    Package Status is Running.

  7. Run showupgradestatus.  

    If Step Status is --, the upgrade process is inactive.

  8. If you have any questions, contact Huawei technical support.