Checking Whether Each Pair Has Dual Controllers

Prerequisites

  • A replacement component is ready.
  • The controller that you want to replace has been located.
    NOTE:
    You can locate components in either of the following ways:
    • On the device view of the management software, view and record the location of the component that you want to replace. For components that have location indicators, turn on the location indicators (for details, see the online help of the management software).
    • Locate the faulty component based on the alarm indicator.
  • The cable connection positions of the controller that you want to replace are labeled on the cables.

Precautions

  • Remove and insert an interface module with even force. Excessive force may damage the appearance or connectors of the interface module.
  • Remove one controller each time to avoid service interruption.
  • If two controllers are faulty, contact Huawei technical support engineers.
  • You are advised to replace a controller module within the shortest time possible.
  • On each controller and data switch in the system (S2600T has no data switch), the ibc_os_hs account must use the default password.
  • After a user manually replaces the public/private key pair of ibc_os_hs, the public/private key pairs of all other functional controllers must be initialized before controller replacement.

    To initialize the public/private key pairs, log in to the serial port of the controller enclosure as user _super_admin (the default password is Admin@revive) and run the initibckey command.

Applicable to S2600T/S5500T V200R002

  1. Replace a controller.

    For details about the S2600T/S5500T, see Replacing a Controller (Applicable to S2600T/S5500T) in OceanStor S2600T&S5500T&S5600T&S5800T&S6800T Storage System V200R002C00 Parts Replacement.

    After replacing a controller, perform the check again to determine whether the check is passed.

    • If yes, no further action is required.
    • If no, go to step 2.

  2. Collect related information and contact technical support engineers.

Applicable to S5600T/S5800T/S6800T V200R002

  1. Replace a controller.

    For details about S5600T/S5800T/S6800T, see Replacing a Controller (Applicable to S5600T/S5800T/S6800T) in OceanStor S2600T&S5500T&S5600T&S5800T&S6800T Storage System V200R002C00 Parts Replacement.

    After replacing a controller, perform the check again to determine whether the check is passed.

    • If yes, no further action is required.
    • If no, go to step 2.

  2. Collect related information and contact technical support engineers.

Applicable to 18500/18800/18800F/HVS85T/HVS88T V100R001

  1. Replace a controller.

    For details about 18500/18800/18800F/HVS85T/HVS88T, see Replacing a Controller (Applicable to 18500/18800/18800F/HVS85T/HVS88T) in OceanStor 18500&18800&18800F Storage System V100R001 Parts Replacement.
    NOTE:
    The way to replace the parts of 18500/18800/18800F/HVS85T/HVS88T is the same as S5600T/S5800T/S6800T.

    After replacing a controller, perform the check again to determine whether the check is passed.

    • If yes, no further action is required.
    • If no, go to step 2.

  2. Collect related information and contact technical support engineers.