Checking the Status of a Replication Link
Procedure
- Check all cable connections.
- If any cable is removed, reinsert it. On the CLI, run the show remote_device link command to check whether Running Status is Link Up. If not, replace the cable.

- If any cable is faulty, replace the cable. On the CLI, run the show remote_device link command to check whether Running Status is Link Up. If not, go to step 2.

- If cable connections are normal, go to step 2.
- Check whether the remote storage array is in normal state.
- If the remote storage array is faulty, rectify the fault. On the CLI, run the show remote_device link command to check whether Running Status is Link Up. If the remote storage array is not faulty, check whether the array is being restarted.

- If the array is being restarted, wait until it is restarted. On the CLI, run the show remote_device link command to check whether Running Status is Link Up. If not, go to step 3.

- If cable connections are normal, go to step 3.
- Collect related information and contact technical support engineers.