Switchover

You can perform the switchover to verify the availability of HyperMetro (NAS) for an existing recovery plan.After the switchover is successful, the primary site stops providing services and host services will be switched to the secondary site.

Prerequisites

Demands in protection objects are described as following table.

Protection Object

Description

FusionCompute VM

After adding disks to or removing disks from a protected VM, manually refresh the information about the VM and execute the protected group where the VM resides to check whether the protected group is valid.

NOTE:

For details about how to refresh the information, see Refreshing Resource Information.

VMware VM

After adding disks to or removing disks from a protected VM, manually refresh the information about the VM and execute the protected group where the VM resides to check whether the protected group is valid.

NOTE:

For details about how to refresh the information, see Refreshing Resource Information.

Context

Because of the importance of switchover, notify the following:

  • Prevent all the system and service administrators from performing other maintenance operations.

Procedure

  1. On the menu bar, select Utilization > Data Restore.
  2. Select the recovery plan that you want to switch and click More > Switch on the Operation list.

    The warning dialog box is displayed.

  3. Perform either of the following operations based on the protected object type.

    If Huawei multipath software has been installed on the Linux-based DR host, ensure the configured I/O hanging time is not 0 and all virtual devices generated by the software have corresponding physical devices. For more details, see the OceanStor UltraPath for Linux xxx User Guide.

    • If a recovery plan of the protection policy template is created based on HyperMetro (NAS) and the protected object type is FusionComputeVM, VMware VM, or NAS File System, perform the following operations:
      1. Click OK.

Result

After the switchover starts, you can view the execution process and result.If the switchover fails, troubleshoot the faults and perform the switchover again.