Description
The communication with remote management server (IP address: {1}) is abnormal.
Attribute
ID
|
Alarm Level
|
Automatically Cleared
|
0x323001B
|
Major
|
Yes
|
Impact on the System
DR fails to be implemented.
Possible Causes
- The connection information about the remote management server is incorrect.
- The network is faulty.
Procedure
- Log in to UltraVR. Click Resources. In the navigation tree, select the remote management server and check its status.
- If the status is Authentication failed=>modify the authentication information and refresh the remote management server. If the alarm persists=>Step 2.
- If the status is Offline=>Step 2.
- Check whether the network is faulty.
- If yes=>recover the network and refresh the remote management server. If the alarm persists=>Step 3.
- If no=>Step 3.
- Contact technical support engineers.