Description
SNMP alarms failed to be authenticated. The alarm source IP address is {0} and SNMP version is {1}.
Attribute
ID
|
Alarm Level
|
Automatically Cleared
|
0x000803220101
|
Major
|
Yes
|
Impact on the System
- Device fault alarms may fail to be received.
- Device access parameters may be maliciously attacked, causing system security risks.
Possible Causes
Fault alarms reported by the NEs failed to be authenticated.
Procedure
- On UltraVR, click Resources. Locate the row where the device resides and choose More > Modify. Check whether SNMP trap alarm report parameters are correctly configured.
- If yes=>Step 2.
- If no=>reconfigure SNMP trap alarm report parameters. If a new device fault alarm cannot be received=>Step 2.
- Contact technical support engineers.