This section describes how to test data in the DR center. DR tests are implemented using snapshot mappings at the DR site to verify the availability of data or snapshots replicated to the DR center. The test process has no adverse impact on the production site. After a test is complete, the test data generated at the recovery site needs to be cleared and resources need to be restored to the status before the test to facilitate subsequent planned migration or fault recovery.
Data test in the DR center is used to verify data availability.
In a DR test, snapshots at the DR site can only be mapped to the initiators. The port mapping mode is not supported.
The DR test is a major operation. During the DR test, pay attention to the following points:
For flash storage, automatic host adding and storage mapping are provided. Ensure that the storage is connected properly to host initiators. In this manner, the system can automatically create hosts, host groups, LUN groups, and mapping views on the storage. The creation principles are as follows:

If Huawei UltraPath has been installed on the Kylin-based DR host, ensure that I/O suspension time is not 0, and virtual devices generated by UltraPath have corresponding physical devices. For details, see the OceanStor UltraPath for Linux xxx User Guide of the corresponding version.