Creating an asynchronous remote replication pair enables you to synchronize data between the primary and secondary sites at a regular interval. Asynchronous remote replication is used in DR scenarios where the distance between the local and remote storage devices is long or the network bandwidth is low.
and select ID, and view the ID of the remote resource whose capacity is the same as that of the local resource.The Create Remote Replication Pair dialog box is displayed on the right.
Parameter |
Description |
|---|---|
Replication Mode |
Set Replication Mode to Asynchronous. |
Sync Type |
Data synchronization mode of the primary and secondary resources. Possible values are:
|
Interval |
Synchronization interval for Timed wait after sync begins and Timed wait after sync ends. [Value range]
NOTE:
This parameter is available only when Sync Method is set to Timed wait after sync begins or Timed wait after sync ends. |
Time Policy |
Specific time policy: The system automatically synchronizes data between primary and secondary resources based on a specific time policy. [Value range]
NOTE:
This parameter is available only when Sync Method is set to Specific time policy. |
Initial Sync |
Mode of initial data synchronization between the primary and secondary resources. Possible values are:
|
Remote Replication Consistency Group |
Consistency group to which the newly created remote replication pair belongs.
NOTE:
If no remote replication consistency group is available, you can click Create to create a remote replication consistency group and add the remote replication pair to the consistency group. |
To query the remote resource ID, log in to the remote device, choose Resources > Volume, click
, and select the desired volume ID.
Parameter |
Description |
|---|---|
Speed |
Data synchronization speed of the remote replication pair. The value ranges from 1 MB/s to 1024 MB/s (or 1024 KB/s to 1,048,576 KB/s).
|
Recovery Policy |
Whether the system automatically synchronizes data after a remote replication fault is rectified. The default value is Automatic. [Value range]
|