Managing Alarm Dump

If you enable the alarm dump function, events and cleared alarms will be automatically dumped to a specific FTP or SFTP server as soon as their number exceeds a system-definable threshold.

Context

To ensure that all events generated by the storage system are retained, it is recommended that you configure alarm dump.

Procedure

  1. Choose Settings > Alarm Settings > Alarm Dump.
  2. Set alarm dump parameters.

    1. Set Enable to the on state.

    2. Set alarm dump parameters. Table 1 describes related parameters.
      Table 1 Alarm dump parameters

      Parameter

      Description

      Transmission Protocol

      Transport protocol of alarm dump, which can be SFTP or FTP.

      NOTE:

      The storage systems support FTP for compatibility concerns. SFTP is recommended for security purposes.

      Username

      User name allowed to log in to the server that stores events and cleared alarms.

      [Value range]
      • The name must be unique.
      • The name contains 1 to 63 characters.
      • The name cannot contain single quotation marks (').

      Password

      Password for logging in to the server. The password contains 1 to 63 characters.

      NOTE:

      You can click Cancel to clear the password so that password authentication will not be performed.

      Confirm Password

      Confirms the password for consistency.

      Server IP Address

      IP address of a server.

      [Value range]
      • In the event of using an IPv4 address:
        • A 32-bit IPv4 address is divided into four 8-bit fields that are expressed in dotted decimal notation.
        • Each field of the IPv4 address must be an integer.
        • The value of the leftmost field ranges from 1 to 223 (excluding 127).
        • The values of the other fields range from 0 to 255.
        • An IPv4 address cannot be set to a special address such as a broadcast address.
      • In the event of using an IPv6 address:
        • A 128-bit IPv6 address is divided into eight 16-bit fields. Each 16-bit field consists of four colon-separated hexadecimal numbers.
        • In each 16-bit field, leading zeros can be omitted for simplicity. However, at least one digit must be reserved in each field.
        • To achieve further simplicity, you can use a double colon (::) in place of a series of zeros. A double colon can be used only once in an IPv6 address. It can also represent the neighboring consecutive zeros at the beginning or end of an IPv6 address.
        • An IPv6 address cannot be set to a special one, such as a network address, loopback address, or multicast address.

      File Save Path

      Path where the alarm information is saved. The path must exist on the server. Otherwise, the dumped alarm information will fail to be saved.

      [Value range]
      • The file save path contains 1 to 255 characters.
      • The file save path cannot contain special characters ':?"<>|*;`$&-()#\! and carriage returns, cannot start with a period (.) or a space, and must end with a slash (/). A path separator / cannot be directly followed by a period (.).
    3. (Optional) Click Test to verify parameter values.
      • If an error dialog box is displayed, at least one parameter value is incorrect. Modify the parameter and retry.
      • If a success dialog box is displayed, the alarm dump parameters have been configured correctly.
    4. Click Save.