Modifying a SmartQoS Policy

This section describes how to modify a user-level QoS policy.

Procedure

  1. Choose Resources > Tuning > SmartQoS > User.
  2. Click More on the right of a desired QoS policy and select Modify.

    The Modify QoS Policy page is displayed.

  3. Set the QoS policy parameters, including the fixed bandwidth upper limit and OPS upper limit.

    1. Set the bandwidth upper limit. that is, the maximum amount of I/O data that can be processed by a single user per second. The unit is MB/s.
    2. Set the OPS upper limit. That is, the maximum number of operations that can be performed by a single user per second.
    3. When the object service is enabled in the storage system, you can choose whether to enable Object Service Read/Write Control to control the upper limits of read and write OPS and bandwidth of the object service. After this function is enabled, you need to set the QoS policy parameters of the object service.

      Table 1 describes related parameters.

      Table 1 Object service QoS policy parameters

      Parameter

      Description

      Read Bandwidth Upper Limit

      Maximum read bandwidth of a single user of the object service. That is, the maximum amount of data in the read requests of the object service delivered by a single user per second. The unit is MB/s.

      Write Bandwidth Upper Limit

      Maximum write bandwidth of a single user of the object service. That is, the maximum amount of data in the write requests of the object service delivered by a single user per second. The unit is MB/s.

      Read OPS Upper Limit

      Read OPS upper limit of a single user of the object service. That is, the maximum number of read requests of the object service that can be delivered by a single user per second.

      Write OPS Upper Limit

      Write OPS upper limit of a single user of the object service. That is, the maximum number of write requests of the object service that can be delivered by a single user per second.

  4. Click OK.