After you set thresholds for system resources, when thresholds are reached, the system generates alarms for notification.
Parameter |
Description |
|---|---|
Insufficient Storage Pool Capacity Alarm Threshold (%) |
When capacity usage of a storage pool reaches this parameter value, an alarm indicating insufficient storage pool capacity is generated. NOTE:
Insufficient storage pool capacity alarm threshold < Severe insufficient storage pool capacity alarm threshold < Storage pool capacity used up alarm threshold |
Severe Insufficient Storage Pool Capacity Alarm Threshold (%) |
When capacity usage of a storage pool reaches this parameter value, an alarm indicating severe insufficient storage pool capacity is generated. NOTE:
Insufficient storage pool capacity alarm threshold < Severe insufficient storage pool capacity alarm threshold < Storage pool capacity used up alarm threshold |
Storage Pool Capacity Used Up Alarm Threshold (%) |
When capacity usage of a storage pool reaches this parameter value, an alarm indicating storage pool capacity used up is generated. NOTE:
Insufficient storage pool capacity alarm threshold < Severe insufficient storage pool capacity alarm threshold < Storage pool capacity used up alarm threshold |
Disk Capacity Alarm Threshold (%) |
When disk capacity usage reaches this parameter value, an alarm is generated. |
CPU Usage Alarm Threshold (%) |
When CPU usage reaches this parameter value, an alarm is generated. |
Memory Usage Alarm Threshold (%) |
When memory usage reaches this parameter value, an alarm is generated. |
Port Usage Alarm Threshold (%) |
When port usage reaches this parameter value, an alarm is generated. |