Aprenda como substituir uma unidade de disco em um local controlado por um sistema ou partição lógica que esteja executando o kernel 2.4 do Linux
Preparar para Remover a Unidade de Disco
Remover a Unidade de Disco
Device Concurrent Maintenance
Type the choices, then press Enter.
Specify either Physical Location or PCI/SCSI location.
Physical Location: U0.1-P1-I4/Z1-A8
OR
PCI/SCSI . . . PCI Bus: PCI Device:
SCSI Channel: SCSI Id: SCSI Lun:
Specify action as 1=Remove device 2=Install device
Action to be performed . . . . . . . . . : 1
Enter a time value between 01 and 19.
Time needed in minutes . . . . . . . . . : 1
Or leave blank and press Enter to cancel
Uma tela Device Concurrent Maintenance Action semelhante à seguinte é mostrada.
Device Concurrent Maintenance Action
Removal of device:
Location: U0.1-P1-I4/Z1-A8
You have 1 minute to perform the operation
During this time, your system can seem unresponsive
c=Confirm q=Cancel
Device Concurrent Maintenance Action In Progress
Please remove the device located in:
Location: U0.1-P1-I4/Z1-A8


A luz de manutenção simultânea para o slot indica que é possível instalar a unidade de disco.
Device Concurrent Maintenance Action
Installation of device:
Location: U0.1-P1-I4/Z1-A8
You have 1 minute to perform the operation
During this time, your system can seem unresponsive
c=Confirm q=Cancel
Uma tela Device Concurrent Maintenance Action In Progress semelhante à seguinte é mostrada.
Device Concurrent Maintenance Action In Progress
Please insert the device located in:
Location: U0.1-P1-I4/Z1-A8
A luz de manutenção simultânea para o slot pára de piscar e permanece acesa quando a unidade de disco está instalada corretamente.