Alternate restart device placement rules for i5/OS logical partitions

After partitions are defined, the Licensed Internal Code and i5/OS® must be loaded from either optical or tape media to the load source disk unit for the logical partition. During partition setup, you must select which I/O processor (IOP) or I/O adapter (IOA) controls the alternate restart device (either tape device or optical device). An IBM® external tape device or optical device that is attached to an IOA that supports alternate restart device can be attached to a system and used as an alternate restart device also.

Note: The information provided does not replace the LPAR Validation Tool (LVT). Use this information as a resource with the LVT output. Its purpose is to assist you in the alternate restart device placement for your i5/OS logical partitions. For more information on the LVT, see LPAR Validation Tool (LVT).

SCSI-to-unit-address conversion

Note: When attaching an external SCSI device as an alternate restart device, it must be at hardware unit address 5, 6, or 7. The following table shows the translation from SCSI to hardware unit addresses.
SCSI address Unit address
2 5
1 6
0 7

Supported internal CD-ROM and DVD-ROM devices

The following table shows the internal CD-ROM and DVD-ROM alternate restart devices that are supported by logical partitions.

Internal optical device feature code 520 and 570 550 595 5074, 5079, 5094, 5294, 5786, 5787, 5790, and 9194
2640 X X    
4625     X X
4630     X X
4631     X X
4633     X X
5751 X X    

i5/OS hardware requirements allow only certain IOPs to be used as the alternate restart IOP. Some of these IOPs must be in specific card slots in the expansions units. The IOP, specified during partition setup, must be in one of the following card slots.

PCI IOP PCI IOA 5074, 5079, 5094, 5294, 5786, 5787, 5790, and 9194

2843 and 2844

PCI WAN/LAN Workstation IOP

2749 Any IOA slot
2757 Any IOA slot
2768 Any IOA slot
2780 Any IOA slot
4748 Any IOA slot
4778 Any IOA slot
5702 Any IOA slot
5703 Any IOA slot

Placement for an internal alternate restart device

The alternate restart device is in the same expansion unit as its controlling IOP or IOA. It must be placed as follows.

Expansion unit Removable media slot
5074, 5079, 5094, 5294, 5786, 5787, 5790, and 9194 D41 or D42
The alternate restart device for an i5/OS logical partition in the system unit must be placed as follows:
Server IOA Removable media slot
520 Imbedded controller P4-D1 or P4-D2
550 Imbedded controller P4-D1 or P4-D2
570 Imbedded controller P4-D1
595 Any valid IOA in the connected base PCI-X expansion unit (9194) Any valid removable media slot in the connected base PCI-X expansion unit (9194)

Internal removable media devices are:

i5/OS logical partitions have a few more rules for alternate restart devices:
  • The alternate restart device must be connected to SCSI bus 0.
  • The alternate restart IOP or IOA is specified during partition setup.
  • IOAs 2757, 2780, 2782, 5702, and 5703 also support disk devices. These IOAs should not be used to attach removable media that will be switched between partitions if disk devices are also attached.