Activate the indicator light for the failing part

The indicator light helps you locate which part to replace. To activate the indicator light, follow these steps:

  1. Log in as root user.
  2. At the command line, type diag and press Enter.
  3. From the Function Selection menu, select Task Selection. Press Enter.
  4. From the Task Selection menu, select Identify and Attention Indicators. Press Enter.
  5. From the list of lights, select the location code for the failing part and press Enter.
  6. Select Commit. This turns on the system attention and indicator light for the failing part.
  7. Exit to the command line.