After replacing a failing part, use this task to deactivate the
failing-part indicator light.
After replacing a failing part, follow these steps to deactivate
the failing-part indicator light:
- Log in as root user.
- At the command line, type /usr/sbin/usysident -s normal
-l<location code> and press Enter. Substitute the
location code of the failing unit for <location code>.
- Look for the system attention light to identify the enclosure that
contains the failing part.