To start a system that is not managed by a Hardware Management
Console (HMC), follow these steps:
- On a rack-mounted system unit, open the front rack door, if necessary. On a stand-alone system unit, open the front door.
- Before you press the power button on the control panel, ensure
that power is connected to the system unit as follows:
- All system power cables are connected to a power source.
- The power-on light F, as shown in the following
figure, is slowly blinking.
- The top of the display D, as shown in the following
figure, contains 01 V=F.

Tip: The system attention light G,
as shown in the previous figure, does not appear on the control panel on the
model 570.
- Press the power button A, as shown in the
following figure, on the control panel.
Note: On the OpenPowerâ„¢ 710 or
model 9110-510, the power
button is on the operations panel.
- Observe the following after pressing the power button:
- The power-on light begins to blink visibly faster.
- The system cooling fans are activated after approximately 30 seconds and
begin to accelerate to operating speed.
- Progress indicators, also referred to as checkpoints, appear on the control
panel display while the system is being started. The power-on light on the
control panel stops blinking and remains on, indicating that system power
is on.
Tip: If pressing the power button does not start the
system, use the following instructions to start the system using the Advanced
System Management Interface (ASMI).