You might need to install or remove an Operations Console cable.
A cable is only required for a local console that is directly
attached or a local console that is directly attached with remote access allowed.
If
you are changing the console device, the server value
QAUTOCFG must
be set to
ON. Use one of the following options
to verify or set this system value on the server:
- Use the WRKSYSVAL QAUTOCFG i5/OS® command.
- During a manual IPL in the IPL Options window, for Set
major system options, select Y. Then for Enable
automatic configuration, select Y.
DANGER
When working on or around the system, observe
the following precautions:
Electrical voltage and current from power, telephone,
and communication cables are hazardous. To avoid a shock hazard:
- Connect power to this unit only with the IBM provided power cord. Do
not use the IBM provided power cord for any other product.
- Do not open or service any power supply assembly.
- Do not connect or disconnect any cables or perform installation, maintenance,
or reconfiguration of this product during an electrical storm.
- The product might be equipped with multiple power cords. To remove all
hazardous voltages, disconnect all power cords.
- Connect all power cords to a properly wired and grounded electrical outlet.
Ensure that the outlet supplies proper voltage and phase rotation according
to the system rating plate.
- Connect any equipment that will be attached to this product to properly
wired outlets.
- When possible, use one hand only to connect or disconnect signal cables.
- Never turn on any equipment when there is evidence of fire, water, or
structural damage.
- Disconnect the attached power cords, telecommunications systems, networks,
and modems before you open the device covers, unless instructed otherwise
in the installation and configuration procedures.
- Connect and disconnect cables as described in the following procedures
when installing, moving, or opening covers on this product or attached devices.
To
Disconnect:
- Turn off everything (unless instructed otherwise).
- Remove the power cords from the outlets.
- Remove the signal cables from the connectors.
- Remove all cables from the devices
To Connect:
- Turn off everything (unless instructed otherwise).
- Attach all cables to the devices.
- Attach the signal cables to the connectors.
- Attach the power cords to the outlets.
- Turn on the devices.
(D005)
Important: It
is assumed the server is powered off. Do not power on the server until you
are instructed to do so.
The following steps assume you have already
set up the PCs that are connecting to the system. You can also use these steps
if you are removing one or more cables from your PC, server, or both.
To
install a console cable, complete the following steps:
This figure is an overview of your system unit, console (PC), and
Operations Console cable. This overview is intended to show you a general
setup. The port location and part numbers might be different depending on
the system and configuration that you have.

Cabling
information is available with instructions and figures to install your cables
for each server model. For cabling instructions, see Cabling your server.