Configure the 7036-P16 as a serial device on an AIX server. - Insure the 7036-P16 and the server are on the network. Ping the 7036-P16
by typing the following command: ping -c 1 [IP Address of target
7036-P16]
If the 7036-P16 responds to the ping, then it is
on the network and the user may proceed to the next step. If the 7036-P16
does not respond to the ping, then the 7036-P16 is not on the network and
the user must perform the network configuration procedure, see Configuring
the 7036-P16 on the network.
- Insure the Digi RealPort Software is installed on the server. Type the
following command: lslpp -l | grep digi
The
response indicates that the "digiasync.realport.obj" is installed.
Note: If
the response indicates the Digi RealPort Software is installed then proceed
to step 3. If there is no response, then the Digi RealPort Software is not
installed and the user must install the Digi RealPort Software, see Configuring
the 7036-P16 on the network.
- Type: smitty devices
- Use the cursor to select: Digi Device and Terminal Servers,
then press Enter.
- Use the cursor to select: Add a Digi Device and Terminal Servers ,
then press Enter
- Use the cursor to select: cts_16_r, then press
Enter.
- Move the cursor to the IP Address box and type: [IP Address],
then press Enter. This is the [IP Address of the target 7036-P16] used in
Step 1.
- Upon successful completion of this command the user will see the following
on the screen: Command: OK stdout: yes
stderr: no Before command completion, additional instructions may
appear. sa[device number] Available
- Press F3
- To configure additional devices, repeat Steps 7. through 10.
- Press F10 to exit from smitty and return to the server's command
line.
This concludes the AIX device configuration portion of this process. After
the serial device is configured, the TTY ports may be configured.