Verifying a repair

Use this information to verify hardware operation after making repairs to the system.

Choose from the following:

  1. Power on the server and all attached I/O enclosures.

    Did all the enclosures power on?
    No Yes
    Continue with the next step. Go to Step 3.

  2. Choose from the following:
    • If the original problem was that an enclosure would not power on and you have another FRU to replace, locate and replace the next FRU.
    • If the next FRU in the FRU list is an isolation procedure, perform the isolation procedure.
    • If the original problem was that an enclosure would not power on and you have an isolation procedure to perform, perform the isolation procedure.
    • If the original problem was that an enclosure would not power on and there are no more FRUs or isolation procedures in the FRU list, contact your next level of support.
    • If you have a new problem, go to Problem Analysis, SA76-0111 and perform problem analysis.

  3. Load the operating system.

    Did the operating system load successfully?
    No Yes
    Continue with the next step. Go to Step 5.

  4. Choose from the following:
    • If the original problem was a failing disk drive that contained the operating system software, go to Step 5.
    • If the original problem was that the operating system would not load and you have another FRU to replace, go to your FRU locations section to locate the next FRU.
    • If the next FRU in the FRU list is an isolation procedure, perform the isolation procedure.
    • If the original problem was that the operating system would not load and you have an isolation procedure to perform, perform the isolation procedure.
    • If the original problem was that the operating system would not load and there are no more FRUs or isolation procedures in the FRU list, contact your next level of support.
    • If you have a new problem, go to Problem Analysis, SA76-0111.

  5. Choose from the following: