FSPSP01

A part vital to system function has been deconfigured. Review the system error logs for errors that callout parts relevant to each reason code. If replacing those parts does not resolve the error, follow the procedure below.

Refer to Locating FRUs for instructions for removing and replacing any FRUs called out by the following procedure.

Perform the following steps:

  1. Is SRC B1xxB10C or B1xxB10D (xx means don't care what Subsystem ID)?
  2. Perform the following steps:
    1. Reseat all of the memory DIMMs in each processor enclosure (primary and all secondary units) but do not replace any memory DIMMs at this time.
    2. Perform a slow boot, refer to Performing a slow boot.

    Does the problem persist?

  3. Use the following procedure to replace each memory DIMM, one at a time, and perform a slow boot after each replacement until the problem is resolved.
    1. Replace the first memory DIMM (for each processor card, starting with processor card 1: Un-P1-Cx-Cy, with x =1 through 4, and 5 through 9, and y =13 through 16).
    2. Perform a slow boot, refer to Performing a slow boot .

    Does the problem persist?

  4. Use the following procedure to replace each memory controller, one at a time, and perform a slow boot after each replacement until the problem is resolved.
    1. Replace the first processor card, starting with processor card 1 (Un-P1-C13 through Un-P1-C16).
    2. Perform a slow boot, refer to Performing a slow boot .

    Does the problem persist?

  5. Is SRC B1xxB107 or B1xxB108?
  6. Is SCR B1xxB106?
  7. Is SRC B1xxB110 or B1xxB111?