FSPSP02
This procedure is for boot failures that terminate very early in
the boot process.
This error path is indicated when the SRC data words are scrolling
automatically through control panel functions 11, 12, and 13, and the control
panel interface buttons are not responsive.
Perform the following:
- Push the white power button to reset the system and bring it up
on the other side of platform LIC.
Note:
The white power button
will only reset the system and attempt to reach standby.
- Did an SRC occur after bringing the system up on the other side?
- No: Refer to the system operations guide and verify
that the system's firmware is at the latest level. Update the system's firmware
on the failing side if necessary.This ends the procedure.
- Yes: Continue with the next step.
- Is the SRC the same SRC that brought you to this procedure?
- No: Return to Starting a Service Call to
service this new SRC. This ends the procedure.
- Yes: Replace the system backplane (Un-P1). Refer
to Locating FRUs. If the problem is not resolved,
contact your next level of support. This ends the procedure.