FSPSP27

An attention line has been detected as having a problem. If the FRU replaced before this procedure did not correct the problem, perform the following:

Refer to Locating FRUs for instructions on replacing any FRUs called out by this procedure.

  1. Was the FRU called out before this procedure a Memory DIMM (Un-P1-C13-Cx or Un-P1-C14-Cx or Un-P1-C15-Cx or Un-P1-C16-Cx)?
  2. Perform the following:
    1. Replace the processor card (Un-P1-C13 or Un-P1-C14 or Un-P1-C15 or Un-P1-C16) that the DIMM was plugged to.
    2. Perform a slow boot

    Does the problem persist?

  3. Perform the following:
    1. Replace the system backplane (Un-P1).
    2. Perform a slow boot. This ends the procedure.
  4. Was the FRU called out before this procedure a Processor Card (Un-P1-C13 or Un-P1-C14 or Un-P1-C15 or Un-P1-C16) or GX Adapter Card (Un-P1-C8 or Un-C1-C7)?
  5. Perform the following:
    1. Replace the system backplane (Un-P1).
    2. Perform a slow boot. This ends the procedure.