The memory cards are plugged in an invalid configuration and cannot
be used by the system.
Refer to Locating FRUs for instructions
for removing and replacing any FRUs called out by the following procedure.
Is the SRC B1xx C02A?
Yes: A memory module is missing from the system.
The additional parts in the FRU callout list will include all memory modules
in the group with the missing card. To correct the error, visually check the
system to determine which of these missing is missing, and add the module. This
ends the procedure.
No: Continue with the next step.
Is the SRC B1xx C029?
Yes: A memory module is a different type than
the other memory modules in the same group. The additional parts in the FRU
callout list will include all memory modules in the group that
contain the error. To correct the error, exchange the memory modules of the
incorrect type with those of the desired type. This ends the procedure.
No: Continue with the next step.
Is the SRC B1xx C02B?
Yes: A group of memory modules are missing and
are required so that other memory modules on the board can be configured.
The additional parts in the FRU callout list will include all missing memory
modules in the group. To correct the error, add or remove these modules to
the desired locations. This ends the procedure.
No: Continue with the next step.
Is the SRC B1xx C036?
Yes: A memory module isn't supported by this system.
The additional parts in the FRU callout list will include all memory modules
in the group that contains the unsupported modules. To correct the error,
remove these modules from the system or replace them with the correct type. This
ends the procedure.