The multi-adapter bridge hardware is having a problem with one or more PCI cards or adapters in the PCI bridge set, but the exact card or adapter cannot be identified.
The problem may be with a card, a card slot, or an embedded adapter. The PCI bridge set is indicated by the Direct Select Address (DSA) in word 7 of the reference code. This symbolic FRU only appears in the serviceable event user interface when the LIC could not determine which PCI bridge set has the problem.
CCIN or FFC
Type and model
Part number
Description
Location code
9406-MMA, 9117-MMA
42R7352
I/O backplane, PCI bridge set 1
Un-P1
9406-MMA, 9117-MMA
42R7352
I/O backplane, PCI bridge set 2
Un-P1, Un-P1-C1, Un-P1-C2
9406-MMA, 9117-MMA
42R7352
I/O backplane, PCI bridge set 3
Un-P1, Un-P1-C3, Un-P1-C4, Un-P1-C5, Un-P1-C6
5790, 7311-D11
80P6626
I/O backplane, PCI bridge set 1
Un-P1, Un-P1-C1, Un-P1-C2, Un-P1-C3
5790, 7311-D11
80P6626
I/O backplane, PCI bridge set 2
Un-P1, Un-P1-C4, Un-P1-C5, Un-P1-C6
0595, 5095, 7311-D20
39J0515
I/O backplane, PCI bridge set 1
Un-P1, Un-P1-C01, Un-P1-C02, Un-P1-C03, Un-P1-C04
0595, 5095, 7311-D20
39J0515
I/O backplane, PCI bridge set 2
Un-P1, Un-P1-C06, Un-P1-C07, Un-P1-C08
5796, 7314-G30
10N7677
I/O backplane, PCI bridge set 1
Un-P1, Un-P1-C1, Un-P1-C2, Un-P1-C3
5796, 7314-G30
10N7677
I/O backplane, PCI bridge set 2
Un-P1, Un-P1-C4, Un-P1-C5, Un-P1-C6
5094
39J3058
I/O backplane, PCI bridge set 1
Un-CB1-C01, Un-CB1-C02, Un-CB1-C03, Un-CB1-C04
5094
39J3058
I/O backplane, PCI bridge set 2
Un-CB1-C05, Un-CB1-C06, Un-CB1-C07, Un-CB1-C08, Un-CB1-C09
5094
39J3058
I/O backplane, PCI bridge set 3
Un-CB1-C11, Un-CB1-C12, Un-CB1-C13, Un-CB1-C14, Un-CB1-C15
This ends the procedure.