DISKPWR

A power supply in a 5786, 5787, 5886, 7031-D24, or 7031-T24 expansion unit might be failing.

Do one of the following:

  • If the SRC that sent you here is 509A1511 or 509A1515, replace the 5886 power supply located in Un-E2. See the following table for the part number and location of the item to replace. If this does not fix the problem, replace the power supply located in Un-E1. This ends the procedure.
  • If the SRC that sent you here is 509A1521 or 509A1525, replace the 5886 power supply located in Un-E2. See the following table for the part number and location of the item to replace. If this does not fix the problem, replace the power supply located in Un-E1. This ends the procedure.
  • Use the following table to determine the part number for the field replaceable unit (FRU):

    CCIN or FFC Type and model Part number Description Location code
      5786, 5787, 7031-D24, 7031-T24 12R9078 Power supply 1 (left) Un-E1
      5786, 5787, 7031-D24, 7031-T24 12R9078 Power supply 2 (right) Un-E2
      5886 39R6547 Power supply 1 (left) Un-E1
      5886 39R6547 Power supply 2 (Right) Un-E2