DISKPWR
A power supply in a 5786, 5787, 5886, 7031-D24, or 7031-T24 expansion unit might be failing.
Do one of the following:
- If the system reference code (SRC) that sent you here is 506x1511 or 506x1515, replace the 5786, 5787, 7031-D24, or 7031-T24 expansion unit power supply located in Un-E1. See the following table for the part number and location of the item to replace. If this does not fix the problem, replace the power supply located in Un-E2.
This ends the procedure.
- If the SRC that sent you here is 506x1521 or 506x1525, replace the 5786, 5787, 7031-D24, or 7031-T24 expansion unit power supply located in Un-E2. See the following table for the part number and location of the item to replace. If this does not fix the problem, replace the power supply located in Un-E1. This ends the procedure.
If the SRC that sent you here is 509A1511 or 509A1515, replace the 5886 power supply located in Un-E2. See the following table for the part number and location of the item to replace. If this does not fix the problem, replace the power supply located in Un-E1. This ends the procedure.
If the SRC that sent you here is 509A1521 or 509A1525, replace the 5886 power supply located in Un-E2. See the following table for the part number and location of the item to replace. If this does not fix the problem, replace the power supply located in Un-E1. This ends the procedure.
Use the following table to determine the part number for the field replaceable unit (FRU):
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
5786, 5787, 7031-D24, 7031-T24 |
12R9078 |
Power supply 1 (left) |
Un-E1 |
| |
5786, 5787, 7031-D24, 7031-T24 |
12R9078 |
Power supply 2 (right) |
Un-E2 |
| |
5886 |
39R6547 |
Power supply 1 (left) |
Un-E1 |
| |
5886 |
39R6547 |
Power supply 2 (Right) |
Un-E2 |