FI00096

FI00096 indicates that the IOP attached to the load-source device is the failing item. Perform the following steps:

  1. Determine if the system has logical partitions. The procedure for determining if the system has logical partitions is available in Determining if the system has logical partitions, or under "Determining if the system has logical partitions" in the service guide for the system unit.
  2. Verify that the IPL type is correct by performing one of the following:
    • If you are using a control panel: Select function 01 on the control panel and press Enter to display the present IPL mode.
    • If you are using the HMC, perform the following steps:
      1. In the Navigation Area, open Systems Management.
      2. Open Servers.
      3. Click the server on which the logical partition is located.
      4. Open Partitions.
      5. Select the logical partition and click the Properties task.
      6. In the Properties window, click the Settings tab.
  3. The failing CFIOP or IOP might have a removable storage I/O adapter FRU. Replace the storage IOA using symbolic FRU STORIOA.
  4. Locate the alternate load source for a system,
  5. Note the device type and refer to the Managing Devices document, order number SA76-0107 to determine the FRU part number to replace.