FI00098

FI00098 indicates that the load-source disk device is the failing item. Perform the following steps:

  1. Determine if the system has logical partitions. The procedure for determining if the system has logical partitions is available in Determining if the system has logical partitions, or under "Determining if the system has logical partitions" in the service guide for the system unit.
  2. Determine the disk unit 1 type number. It is printed on a label on the front of the system frame.
  3. If the system does not have a label that identifies the disk unit type, you can determine the part number of the disk unit by looking at a label located on the disk unit. You must remove the disk unit to see this label.
  4. Exchange the disk drive and logic card for the disk unit type you have.
  5. Locate the alternate load source device for the system.
  6. Note the device type and refer to the Managing Devices document, order number SA76-0107 to determine the FRU part number to replace.