FI01141
FI01141 indicates that a loss of power to an IOP, to an internal device, or to an external device may have occurred.
Perform the following steps:
- Are 0000 xxxx, 1xxx xxxx, or A6xx 698x SRCs displayed on the control panel?
- No: Continue with the next step.
- Yes: Use the SRC displayed on the control panel to diagnose the problem.
- Did the SRC that directed you to this FI code involve an externally attached device or an IOP with an externally attached device?
- No: Continue with the next step.
- Yes: Verify that there is no obvious problem with power to the device. If you suspect a power problem with the device, go to the service information for that external device.
- The power supply cables or connections to internal disk units, tape units, diskette units, or optical storage units may be the failing item.
- For cable information, note the cable type and refer to the Site and Hardware Planning document, order number SA76-0091 to determine the FRU part number to replace.
For part numbers, see Part Information