FI02112

FI02112 indicates that the addressed storage device is the failing item.

Perform the following steps:

  1. Is the device location information available in the Service Action Log?
    • No: Continue with the next step.
    • Yes: Exchange the failing item.
  2. Find the IOP address and the device address. See System reference code (SRC) address formats, or see "System reference code (SRC) address formats" in the service guide for the system unit.
  3. To determine the location of the I/O processor card, see Physical Locations, or see "Physical Locations" in service guide for the system unit on which you are working Then, find:
    • The IOP card location identified by the direct select address.
    • The addressed storage device location identified by the device address.
  4. Exchange the failing device. Possible failing addressed devices include disk, tape, optical, device backplane, or Auxiliary Cache IOA. Use the device type to determine the part.

    For device FRU part numbers, refer to the Managing Devices document, order number SA76-0107.