If you receive symbolic FRU FWLPAR, perform one of the following:
- If a location code was reported with the error, Probing failed for the PCI slot connector:
- Check for platform firmware updates. Apply the update if there is one available. For firmware update procedures, refer to the system unit service guide.
- Check for adapter firmware updates, apply if available. If there are no updates available, replace the adapter, see Managing PCI Adapters, order number SA76-0092 for PCI adapter FRU part numbers. If this does not resolve the problem, replace the I/O backplane on which the slot connector is located, use the following table to determine the part number for the field replaceable unit (FRU):
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
8204-E8A |
10N9369 |
System backplane |
Un-P1 |
| |
9406-MMA, 9117-MMA |
42R7352 |
I/O backplane |
Un-P1 |
| |
5790, 7311-D11 |
80P6626 |
I/O backplane |
Un-P1 |
| |
0595, 5095, 7311-D20 |
39J0515 |
I/O backplane |
Un-P1 |
| |
5796, 7314-G30 |
10N7677 |
I/O backplane |
Un-P1 |
If no location code was reported with the error, The connector
was not found:
- Check for platform firmware updates, apply if available. For firmware update procedures, refer to the system unit service guide.
- If no updates are available, contact your next level of support.
This ends the procedure.