FWPCI4
If you receive the FWPCI4 symbolic FRU, perform the following.
- If a location code is associated with the checkpoint, replace the
adapter identified by the location code. See Managing PCI Adapters, order number SA76-0092 for PCI adapter FRU part numbers.
- If no location code is specified, go to PFW1542: I/O problem isolation procedure,
or see "PFW1542: I/O problem isolation procedure" in the service guide for the server.
This ends the procedure.