FWPCI5

If you receive symbolic FRU FWPCI5, perform the following procedure:

  1. Is a location code associated with the checkpoint?
  2. Replace the following, one at a time, until the problem is resolved:
    1. The FRU identified by the location code, see the system unit service guide for the FRU part numbers.
    2. I/O backplane, use the following table to determine the part number for the field replaceable unit (FRU):

      CCIN or FFC Type and model Part number Description Location code
        8204-E8A 10N9369 System backplane Un-P1
        9406-MMA, 9117-MMA 42R7352 I/O backplane Un-P1
        5790, 7311-D11 80P6626 I/O backplane Un-P1
        0595, 5095, 7311-D20 39J0515 I/O backplane Un-P1
        5796, 7314-G30 10N7677 I/O backplane Un-P1
        5094 39J3058 I/O backplane Un-CB1

      This ends the procedure.