FWSCSI5
If you receive the symbolic FRU FWSCSI5, before replacing any system components do the following:
- Ensure that the controller and each device on the SCSI bus is assigned a unique SCSI ID.
- Ensure that the SCSI bus is properly terminated.
- Ensure that the SCSI signal and power cables are securely connected and are not damaged.
The location code information is required to identify the ID of SCSI device failures as well as to indicate the location of the controller to which the device is attached. Check the system error logs to determine the location code information associated with the error code.
- Replace the SCSI device. See Managing Devices, order number SA76-0107 for SCSI device FRU part numbers.
- Replace the SCSI cable. See Site and Hardware Planning, order number SA76-0091 for SCSI cabling FRU part numbers.
- If the missing SCSI devices are connected to the same backplane, replace the SCSI backplane. Use the following table to determine the part number for the field replaceable unit (FRU):
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
9406-MMA, 9117-MMA |
42R6780 |
Disk drive backplane |
Un-P3 |
Replace the SCSI controller.See Managing PCI adapters, order number SA76-0092 for SCSI PCI adapter FRU part numbers. If the failure is on an integrated SCSI controller, replace the I/O backplane, use the following table to determine the part number for the field replaceable unit (FRU):
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
9406-MMA, 9117-MMA |
42R7352 |
I/O backplane |
Un-P1 |
This ends the procedure.