HSL_LNK

The failing component is the RIO/HSL/12X connection.

Attention: When a RIO/HSL cable is disconnected, it might result in a lost connection between the units even after the cable is reconnected. To fix this problem, you need to cycle power on the unit with the locked RIO/HSL connection. This problem does not occur with 12X cables.

Note: If question marks (???) appear at the end of the location code, then the port could not be determined. Use the location code associated with the other end of the cable. If question marks appear for both port locations, use the isolation procedures suggested in the reference code information for this SRC.

  1. Choose from the following:
    • If you were sent to this procedure from another symbolic field replaceable unit (FRU), locate that FRU in Table 1 to see the description of the RIO/HSL/12X FRU. Then continue with the next step for more information about the FRU.
    • If you are working with this symbolic FRU in the FRU list, the failing component is a RIO/HSL/12X connection. Diagnostic code could not determine what kind of hardware was involved. The RIO/HSL/12X hardware can be any of the following:
      • Cable
      • Embedded RIO/HSL/12X link in a FRU (a backplane, for example)
      • RIO/HSL/12X interposer card
      The RIO/HSL/12X link is on or between the other FRU or FRUs listed for the reference code. Continue with the next step.

    Table 1. RIO/HSL symbolic FRUs
    RIO/HSL FRU Description
    HSL_OPT This is an optical RIO/HSL cable.

    When exchanging optical RIO/HSL cables, use the optical cleaning kit and procedures. See symbolic FRU OPT_CLN for details.

    If an interposer card is called for, be sure the interposer type matches the cable type (optical or copper).

    HSL1 There is a standard copper RIO/HSL cable at both ends (yellow connectors).
    HSL1_UN There is a standard copper RIO/HSL cable (yellow connector) at the detecting end, and an unknown connector type at the other end.
    HSL2 There is a copper HSL2/RIO-G cable at both ends (black connectors), but the length of the cable could not be sensed.
    HSL2_xx There is a copper HSL2/RIO-G cable at both ends (black connectors). Use the xx value to determine the cable length from this list:
    • HSL2_01 = 1 meter HSL2 cable
    • HSL2_03 = 3 meter HSL2 cable
    • HSL2_08 = 8 meter HSL2 cable
    • HSL2_10 = 10 meter HSL2 cable
    • HSL2_15 = 15 meter HSL2 cable
    • HSL2_17 = 1.75 meter HSL2 cable
    • HSL2_25 = 2.5 meter HSL2 cable
    HSL_IB This is a 12X cable (green connectors)
    HSL_I There is a RIO/HSL interposer card for HSL/RIO cables (yellow connectors), HSL2/RIO-G cables (black connectors), or optical cables. The interposer card type could not be sensed.
    HSL_I2
    HSL_I3
    HSL_I4
    There is a RIO/HSL interposer card for HSL/RIO cables (yellow connectors), HSL2/RIO-G cables (black connectors), or optical cables. Use the x value to determine the interposer card type from this list:
    • HSL_I2 = Copper HSL2/RIO-G interposer card for HSL2/RIO-G cable connectors (black) in the system unit backplane position C08 or C09 of machine type 9406 model 825.
    • HSL_I3 = Optical HSL/RIO interposer card for optical RIO/HSL cables in system unit backplane position C08 or C09 of machine type 9406.

  2. Choose from the following options:
    • If you are working from the serviceable event view, the location code or FRU description in the view will help determine the actual RIO/HSL/12X hardware to exchange. Continue with the next step.
    • If you are not working from the serviceable event view, or the view does not have a location code or better FRU description, then determine the location code of other FRUs in the FRU list for the error. Then continue with the next step.

  3. Use the location code and the information from the preceding table to determine the machine type, model, or unit feature involved in the error. If necessary, use the location code for other FRUs listed in the FRU list for this error to determine the failing RIO/HSL/12X connection and any related FRUs that are part of that connection. Use the following table to determine the part number for the FRU:

    Note: If you exchange all of the FRUs in the FRU list, but the problem still exists, contact your next level of support. You might be directed to exchange additional RIO/HSL/12X FRUs. Additional RIO/HSL/12X FRUs has more information about RIO/HSL/12X FRUs on specific models and I/O enclosures. Use this section when you are directed by your next level of support.

    Table 2. RIO/HSL/12X FRU parts
    CCIN or FFC Type and model Part number Description Location code
      8204-E8A See RIO/HSL/12X cables RIO/HSL cables Un-P1-Cx-Ty
      8204-E8A 10N9180 RIO-2/HSL-2 adapter Un-P1-Cx
      8204-E8A 10N9369 System backplane Un-P1
      9406-MMA, 9117-MMA See RIO/HSL/12X cables RIO/HSL cables Un-P1-Cx-Ty
    1800 9406-MMA, 9117-MMA 39J0792 RIO/HSL-2 adapter Un-P1-Cx
      9406-MMA, 9117-MMA 42R7352 I/O backplane Un-P1
    28FF 5790, 7311-D11 03N5633 RIO/HSL adapter Un-P1-C7
      5790, 7311-D11 80P6626 I/O backplane Un-P1
    2887 0595, 5095, 7311-D20 39J0527 RIO/HSL-2 adapter Un-P1-C05
    28E7 0595, 5095, 7311-D20 39J0523 RIO/HSL adapter Un-P1-C05
      0595, 5095, 7311-D20 39J0515 I/O backplane Un-P1
    520A 5796, 7314-G30 10N8782 Dual-port 12X channel attach adapter Un-P1-C7
      5796, 7314-G30 10N7677 I/O backplane Un-P1

    Use the following table to determine FRU part numbers for RIO/HSL cables. To locate part numbers for GX Dual-Port 12X cables and any cables that are not listed here, see the Site and Hardware Planning Guide, order number SA76-0091.

    Table 3. Cable part numbers
    Description Part number
    RIO/HSL cable (3 meters) (1460) 44L0005
    RIO/HSL cable (6 meters) (1461) 97H7490
    RIO/HSL cable (15 meters) (1462) 04N7014
    RIO/HSL optical cable (6 meters) (1470) 21P5014
    RIO/HSL optical cable (30 meters) (1471) 21P5015
    RIO/HSL optical cable (100 meters) (1472) 21P5016
    RIO/HSL optical cable (250 meters) (1473) 21P6326
    RIO/HSL to RIO/HSL-2 (6 meters) (1474) 21P5477
    RIO/HSL to RIO/HSL-2 (10 meters) (1475) 21P5458
    RIO/HSL-2 (1.2 meters) (1481, 3146) 21P5454
    RIO/HSL-2 (1.75 meters) (1307, 3156) 00P5238
    RIO/HSL-2 (1.75 meters) (1308, 3158) 00P5239
    RIO/HSL-2 (3.5 meters) (1482, 3147) 53P2676
    RIO/HSL-2 (10 meters) (1483, 3148) 21P5456
    RIO/HSL-2 (15 meters) (1485) 21P5457
    RIO/HSL (8 meters) (3170) 12R7503

Additional RIO/HSL/12X FRUs

The following are RIO/HSL/12X FRUs by model or unit type. For the model or unit type you are working on, there might be additional RIO/HSL/12X FRUs which were not listed in the FRU list of the error. Under the direction of your next level of support, you can try exchanging the additional FRUs.

  1. In the following table, locate the unit type(s) on which you are working. Exchange the indicated RIO/HSL/12X loop connections (external or embedded) or RIO/HSL/12X interposer card.

    Table 4. RIO/HSL/12X FRU parts
    CCIN or FFC Type and model Part number Description Location code
    2886 5094, 5096, 5294, 5296 39J0669 HSL (optical) I/O bridge adapter Un-CB1-C10
    2887 5094, 5096, 5294, 5296 39J0527 HSL I/O bridge adapter Un-CB1-C10
    28E7 5094, 5096, 5294, 5296 39J0523 HSL-2 I/O bridge adapter Un-CB1-C10
    28FF 5790, 7311-D11 03N5633 RIO/HSL adapter Un-P1-C7
    2886 0595, 5095 39J0669 HSL (optical) I/O bridge adapter Un-P1-C5
    2887 0595, 5095, 7311-D20 39J0527 RIO/HSL I/O bridge adapter Un-P1-C5
    28E7 0595, 5095, 7311-D20 39J0523 RIO/HSL-2 I/O bridge adapter Un-P1-C5
    520A 5796, 7314-G30 10N8782 Dual-port 12X adapter Un-P1-C7
      1519 42R4468 Integrated xSeries Adapter  
  2. Did the exchange correct the error?
    • Yes: The FRU you just replaced was the failing item.

      This ends the procedure.

    • No: Call your next level of support.

      This ends the procedure.