MABRDG

The problem is the multi-adapter bridge hardware on a system bus.

Perform the following:

  1. Is the location information for this failing component available in the problem view you are working with of the serviceable event user interface of an operating system, service processor, or Hardware Management Console (HMC)?
    • No: Record the bus number value, BBBB, in word 7 of the reference code and continue with the next step.
    • Yes: Use this location information and continue with the next step.

  2. The failing component is the FRU containing the multi-adapter bridge. Use the following table to identify the name of the FRU that is indicated by the location in the user interface you are working with, or by using the bus number you obtained previously in this procedure to exchange the FRU.

CCIN or FFC Type and model Part number Description Location code
  8204-E8A 10N9369 System backplane Un-P1
  9406-MMA, 9117-MMA 42R7352 I/O backplane Un-P1
  5790, 7311-D11 80P6626 I/O backplane Un-P1
  0595, 5095, 7311-D20 39J0515 I/O backplane Un-P1
  5796, 7314-G30 10N7677 I/O backplane Un-P1
  5094 39J3058 I/O backplane Un-CB1

This ends procedure.