Use this topic to view memory and location information for the 2890 and 2892 Integrated xSeries® Server (IXS) cards.
Memory for 2890 Integrated xSeries Server (IXS) cardFigure 1. Locations of DIMM 0, DIMM 1, DIMM 2 and DIMM 3 on 2890 Integrated xSeries Server (IXS) card.

One of the Pentium® memory modules (DIMM 0, DIMM 1, DIMM 2, or DIMM 3) may be the failing item. See the table below.
Feature
Size
2795/2895
128 MB
2796/2896
256 MB
2797/2897
1 GB
Notes:
Memory for 2892 Integrated xSeries Server (IXS) card
Figure 2. Locations of DIMM 0, DIMM 1, DIMM 2 and DIMM 3 on 2892 Integrated xSeries Server (IXS) card

One of the Pentium memory modules (DIMM 0, DIMM 1, DIMM 2, or DIMM 3) might be the failing item. See the table below.
Feature
Size
0426/0446
512 MB
0427/0447
1 GB
Note: At least two Pentium memory modules are required in positions DIMM 0 and DIMM 1, or positions DIMM 2 and DIMM 3
Use the following table to determine the part number for the field replaceable unit (FRU):
CCIN or FFC
Type and model
Part number
Description
Location code
0446
2892-001, 2892-002
26P0989
512 MB IXS DDR memory module
0447
2892-001, 2892-002
26P1159
1 GB IXS DDR memory module
2895
2890-001, 2890-002, 2890-003
29L0955
128 MB IXS memory module
2896
2890-001, 2890-002, 2890-003
29L0956
256 MB IXS memory module
2897
2890-001, 2890-002, 2890-003
29L0957
1 GB IXS memory module
2890-001, 2890-002, 2890-003
08J0653
DIMM, IXS 2890 adapter card IOP