PWRSPLY
A power supply might be the failing item.
Attention: When replacing a redundant power supply, a 1xxx 1504, 1514, 1524, or 1534 reference code may surface in the error log.
If you just removed and replaced the power supply in the location associated
with this reference code, and the power supply became ready (ac power good LED is illuminated) after the install,
disregard this reference code. If you had not previously removed and replaced
a power supply, the power supply did not become ready after installation, or
there are repeated fan fault errors after the power supply replacement, continue
to follow this procedure.
- Is the reference code 1xxx15xx or 1xxx71xx?
- No: Continue with the next step.
- Yes: Perform the following:
- Find the unit reference code in the following table to
determine FRU part number for the failing power supply and it's location.
- Ensure that the power cables to the power supply are properly connected and seated. The green Power Good LED on the power supply will illuminate when power is correctly connected to the power supply.
- Is the reference code 1xxx-1500, 1510, 1520, or 1530 and is the failing
unit configured with a redundant power supply option (or dual line cord feature)?
- Yes: Before replacing any parts, perform isolation procedure PWR1911, or perform isolation procedure PWR1911 in the service guide for the server.
- No: Continue with step 1.d.
-
Replace the failing power supply (see the following table to determine which power supply to replace and its location).
Attention: For reference codes 1510 and 1520 before replacing any parts on a dual line cord system, perform isolation procedure PWR1911, or perform isolation procedure PWR1911 in the service guide for the server.
Before replacing parts on a single line cord system, check the ac jumper to the power supply.
- Perform the following if the new power supply does not fix the problem:
- Reinstall the original power supply.
- Try the new power supply in each of the other positions listed in the table.
- If the problem still is not fixed, reinstall the original power supply and go to the next FRU in the list.
- For reference codes 1xxx-1510 and 1520 if a problem persists after replacing the power supply, exchange the power distribution backplane, contact your next level of support.
Use the following table to determine the part number for the field replaceable unit (FRU):
| Unit reference code |
Type-model or feature code |
Part number |
Description |
Location code |
| 1510, 1511, 1512, 1513, 1514, 7110 |
8204-E8A |
44V3559 |
Power supply, ac |
Un-E1 |
| 1520, 1521, 1522, 1523, 1524, 7120 |
8204-E8A |
44V3559 |
Power supply, ac |
Un-E2 |
| 1510, 1511, 1512, 1513, 1514, 7110 |
8204-E8A |
42R6607 |
Power supply, dc |
Un-E1 |
| 1520, 1521, 1522, 1523, 1524, 7120 |
8204-E8A |
42R6607 |
Power supply, dc |
Un-E2 |
| 1510, 1511, 1512, 1513, 1514, 7110 |
9406-MMA, 9117-MMA |
42R8010 |
Power supply |
Un-E1 |
| 1520, 1521, 1522, 1523, 1524, 7120 |
9406-MMA, 9117-MMA |
42R8010 |
Power supply |
Un-E2 |
| 1510, 1511, 1512, 1513, 1514, 1516, 1517 |
5790, 7311-D11 |
22R3958 |
Power supply |
Un-E1 |
| 1520, 1521, 1522, 1523, 1524, 1526, 1527 |
5790, 7311-D11 |
22R3958 |
Power supply |
Un-E2 |
| 1510, 1511, 1512, 1513, 1514, 1516, 1517 |
0595, 5095, 7311-D20 |
39J2781 |
Power supply |
Un-E1 |
| 1520, 1521, 1522, 1523, 1524, 1526, 1527 |
0595, 5095, 7311-D20 |
39J2781 |
Power supply |
Un-E2 |
| 1510, 1511, 1512, 1513, 1514, 1516, 1517 |
5796, 7314-G30 |
42R4491 |
Power supply |
Un-E1 |
| 1520, 1521, 1522, 1523, 1524, 1526, 1527 |
5796, 7314-G30 |
42R4491 |
Power supply |
Un-E2 |
This ends the procedure.
-
Is the reference code 1xxx-2600, 2601, 2603, 2605, or 2606?
- Is the reference code 1xxx 8455 or 8456?
- No: Return to the "Starting a service call" procedure. This ends the procedure.
- Yes: One of the power supplies is missing, and must be installed. Use the following table
to determine which power supply is missing, and install the power supply.
| Reference code |
Missing power supply |
| 1xxx 8455 |
Un-E1 |
| 1xxx 8456 |
Un-E2 |