SIIOADP: RIO adapter/HSL I/O bridge (in a system unit or I/O expansion unit).
Note: In the following procedures, the term RIO adapter refers to either a RIO adapter or an HSL I/O bridge, depending on the server to which it applies.
Example: Decoding FRU Callout 00044000 Loop location information and diagram for 8204-E8A Loop location information and diagram for 9117-MMA and 9406-MMA
9406-MMA and 9117-MMA RIO loop diagram
1 B7006981 RIO/HSL (bridge) bus adapter failure SRC
2 XXXXXX62 SRC Format 62
3 00010002 Component ID field must be an exact match
4 14993203 Code Model and PRC must be an exact match
5 FRUCALLO Decode this when the SRC is 6906 or 6907
6 FRUCALLO Decode this when the SRC is 6981
7 00000000
Example: SRC 6981
1 B7006981
2 00000062
3 00010002
4 14993203
6 00044000
7 00000000
When immediate termination occurs, the SRC does
not provide a FRU callout. The following steps describe how to determine the
FRU callout.

Hub (decimal)
Loop number
(hex / dec)Location code for leading port of the loop
1
0686/1670
P1-C8-T2
1
0781/1921
P1-C8-T2
2
0688/1672
P1-C7-T2
2
0782/1922
P1-C7-T2
System unit drawer
Hub (decimal)
Loop number
(hex / dec)Location code for leading port of the loop
0
1
0686/1670
P1-C8-T2
0
1
0781/1921
P1-C8-T2
0
2
0688/1672
P1-C9-T2
0
2
0782/1922
P1-C9-T2
1
9
0696/1686
P1-C8-T2
1
9
0789/1929
P1-C8-T2
1
10
078A/1930
P1-C9-T2
1
10
0698/1688
P1-C9-T2
2
17
06A6/1702
P1-C8-T2
2
17
0791/1937
P1-C8-T2
2
18
06A8/1704
P1-C9-T2
2
18
0792/1938
P1-C9-T2
3
25
06B6/1718
P1-C8-T2
3
25
0799/1945
P1-C8-T2
3
26
06B8/1720
P1-C9-T2
3
26
079A/1946
P1-C9-T2
Note: Concurrent maintenance requires that you make a change
to the previous procedure for counting the RIO adapters on the loop. If concurrent
maintenance was performed to attach one or more additional RIO adapters to
this loop and the server has not been IPL'ed after the adapters were added,
then exclude the added RIO adapters as you make the initial count.
If the RIO loop position exceeds the number of RIO adapters, continue by counting
the added RIO adapters in the order they were added to the loop.
CCIN or FFC
Type and model
Part number
Description
Location code
1800
9406-MMA, 9117-MMA
39J0792
RIO-2/HSL-2 adapter
Un-P1-Cx
1802
8204-E8A
10N9369
RIO-2/HSL-2 adapter
Un-P1-Cx
2886
5094, 5096, 5294, 5296
39J0669
HSL (optical) I/O bridge adapter
Un-CB1-C10
2887
5094, 5096, 5294, 5296
39J0527
HSL I/O bridge adapter
Un-CB1-C10
28E7
5094, 5096, 5294, 5296
39J0523
HSL-2 I/O bridge adapter
Un-CB1-C10
28FF
5790, 7311-D11
03N5633
RIO/HSL-2 adapter card
Un-P1-C7
2886
0595, 5095, 7311-D20
39J0669
RIO/HSL (optical) adapter card
Un-P1-C05
2887
0595, 5095, 7311-D20
39J0527
RIO/HSL adapter card
Un-P1-C05
28E7
0595, 5095, 7311-D20
39J0523
RIO/HSL-2 adapter card
Un-P1-C05
1519
42R4468
Integrated xSeries(R) adapter (IXA)