SI_PHB
The HSL I/O bridge/RIO adapter hardware in a system or I/O unit is failing.
Follow this procedure to identify the failing component to exchange.
- Are you working from the serviceable event view and a card location
is listed with this FRU?
- Yes: Then the listed card location is where the error is located. Continue with the next step.
- No: Record the bus number value, BBBB,
in word 7 of the reference code. Word 7 of the reference code allows you to determine the correct bus number, bus type, multi-adapter bridge number, multi-adapter bridge function number, and logical card number from the Direct Select Address (DSA). See the section entitled, "Breaking down a RIO/HSL or PCI bus reference code" in the service guide for the system unit on which you are working.
Search for the decimal bus number, using one of the following, to determine
which frame or I/O unit contains the failing item.
- the HMC's system configuration user interface (if an HMC is controlling the system)
- i5/OS® Hardware Service Manager (HSM)
- or the System Configuration Listing
Record the unit type or feature and continue with the next step.
- Use the following table to determine the part number for the field replaceable unit (FRU):
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
8204-E8A |
10N9369 |
System backplane |
Un-P1 |
| |
9406-MMA, 9117-MMA |
42R7352 |
I/O backplane |
Un-P1 |
| |
5790, 7311-D11 |
03N5633 |
RIO/HSL adapter |
Un-P1-C7 |
| |
0595, 5095, 7311-D20 |
39J0523 |
RIO/HSL adapter |
Un-P1-C05 |
| |
5796, 7314-G30 |
10N8782 |
RIO/HSL adapter |
Un-P1-C7 |
This ends the procedure.