SI_PHB

The HSL I/O bridge/RIO adapter hardware in a system or I/O unit is failing.

Follow this procedure to identify the failing component to exchange.

  1. Are you working from the serviceable event view and a card location is listed with this FRU?
    • Yes: Then the listed card location is where the error is located. Continue with the next step.
    • No: Record the bus number value, BBBB, in word 7 of the reference code. Word 7 of the reference code allows you to determine the correct bus number, bus type, multi-adapter bridge number, multi-adapter bridge function number, and logical card number from the Direct Select Address (DSA). See the section entitled, "Breaking down a RIO/HSL or PCI bus reference code" in the service guide for the system unit on which you are working. Search for the decimal bus number, using one of the following, to determine which frame or I/O unit contains the failing item.
      • the HMC's system configuration user interface (if an HMC is controlling the system)
      • i5/OS® Hardware Service Manager (HSM)
      • or the System Configuration Listing
      Record the unit type or feature and continue with the next step.

  2. Use the following table to determine the part number for the field replaceable unit (FRU):

    CCIN or FFC Type and model Part number Description Location code
      8204-E8A 10N9369 System backplane Un-P1
      9406-MMA, 9117-MMA 42R7352 I/O backplane Un-P1
      5790, 7311-D11 03N5633 RIO/HSL adapter Un-P1-C7
      0595, 5095, 7311-D20 39J0523 RIO/HSL adapter Un-P1-C05
      5796, 7314-G30 10N8782 RIO/HSL adapter Un-P1-C7

This ends the procedure.