The service processor is failing. Use the table below to determine the FRU part number for the service processor. Some units have the service processor built into the system backplane.
Note: After you replace the part and before attempting to power up the server, set the configuration ID for the SPCN. Otherwise, the server will not IPL. For information about setting the configuration ID, see PWR1917 or go to the PWR1917 procedure in the service guide for the server.
If the server is a multiple-drawer 9406-MMA or 9117-MMA server and the SRC is a B1xx SRC, use the last byte in word 3 of the primary SRC to determine which service processor card to replace:
If you don't have access to word 3 of the primary SRC, you can also determine which service processor card to replace by using either of the following methods:
Use the following table to determine the part number for the field replaceable unit (FRU):
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 8204-E8A | 10N9369 | System backplane (service processor is part of the system backplane for the 8204-E8A) | Un-P1 | |
| 9406-MMA, 9117-MMA | 10N8752 | Service processor card (service interface card) | Un-P1-C11 |
This ends the procedure.